1. Product Overview

The SICK STR1-SAFM0AC8 is an RFID non-contact safety switch for monitoring movable guards and safety doors. SICK part number 1069566. It provides two self-monitoring semiconductor safety outputs (OSSDs), one auxiliary output complementary to the OSSDs, and is specified to PL e / SIL 3 / Category 4 / Type 4.

latest company case about SICK STR1-SAFM0AC8: RFID Safety Switch — PFHD, Coding Level and Series Connection Guide  0

Three attributes define its selection identity beyond the “RFID safety switch” label.

Coding: universal, low coding level. Any actuator of the same type will trigger the sensor. SICK’s STR1 series also offers unique and permanent coding; those variants require an actuator to be taught in, after which the sensor accepts only that actuator. The choice is not a preference — it is determined by whether the risk assessment identifies a reasonably foreseeable incentive to substitute an actuator.

PFHD: 5.1 × 10⁻⁹ at sea level, 14 × 10⁻⁹ at 2,000 m. The difference matters for installations at altitude. Both values are far below the PL e threshold, but the safety validation document should use the value that matches the installation altitude.

Series connection: 0.1 s per additional downstream switch. The single-sensor response time is 40 ms. In a safe series connection, each downstream sensor adds 0.1 s to the system response time. A 10-switch series connection is not 40 ms × 10; it follows the calculation in Section 7.

The switch operates from 24 V DC, connects through an 8-pin M12 connector with a 0.2 m cable, and carries IP67 / IP69K ratings. The housing is VISTAL, 40 × 18 × 26 mm.

2. Technical Specifications
Parameter Specification
Manufacturer SICK
Model STR1-SAFM0AC8
Part number 1069566
Sensor principle RFID
System components Sensor with actuator
Actuator design Flat
Coding Universally coded
Actuator coding level Low coding level (EN ISO 14119)
Safe outputs 2 OSSDs
Auxiliary output 1 AUX, complementary to OSSDs
Active sensor surfaces 3 (top, left side, right side)
Actuation directions 5
Assured switch-on distance Sao 14 mm (-10 to +70 °C); 10 mm (-30 to -10 °C)
Assured switch-off distance Sar 28 mm
Supply voltage 24 V DC (19.2–28.8 V DC)
Output type Self-monitoring semiconductor outputs (OSSDs)
Output current ≤100 mA
Power consumption 50 mA
Response time 40 ms (single sensor)
Release time 100 ms
Risk time 80 ms
Switch-on time (power-up delay) 2.5 s
Connection 0.2 m cable, 8-pin M12 connector
Enclosure rating IP67 / IP69K
Operating temperature -30 to +70 °C for serial numbers 1825 and higher; -10 to +70 °C for earlier serial numbers
Housing dimensions 40 × 18 × 26 mm
Housing material VISTAL
PFHD 5.1 × 10⁻⁹ /h at 40 °C, sea level; 14 × 10⁻⁹ /h at 40 °C, 2,000 m altitude
Safety integrity SIL 3 (IEC 61508); SILCL 3 (EN 62061)
Performance level PL e (EN ISO 13849)
Category Category 4 (EN ISO 13849)
Safety switch type Type 4 (EN ISO 14119)
Mission time (TM) 20 years (EN ISO 13849)

The serial-number temperature boundary is not a footnote. The -30 °C rating applies only to units with serial numbers beginning at 1825 or higher. A unit from an earlier batch is rated -10 to +70 °C. In a cold-storage or outdoor installation, the nameplate serial number determines whether the switch is suitable before any wiring is done.

PFHD is altitude-dependent. The 5.1 × 10⁻⁹ figure applies at sea level. At approximately 2,000 m, SICK specifies 14 × 10⁻⁹ /h. For a machine installed at altitude, the safety validation calculation should use the altitude-corrected value. Both numbers are well below the PL e threshold of 10⁻⁷ /h, but the correct value is the one that matches the installation altitude, not the smaller of the two.

3. How RFID Safety Switching Works

The sensor is mounted on the fixed machine frame; the actuator is mounted on the movable guard. When the guard closes and the actuator enters the response range, the RFID interaction enables the OSSDs after the internal self-checks pass. When the actuator leaves the response range, the OSSDs switch OFF within the response time (40 ms), and the connected safety evaluation unit initiates the machine stop.

The AUX output is complementary to the OSSDs. It is intended for non-safety signalling and must not be wired into the safety path. The two OSSDs and the two enable inputs (pins 4 and 8) are the safety-related connections; the pin assignment is in Section 6.

4. Universal Coding and What “Low Coding Level” Actually Means

The STR1-SAFM0AC8 is universally coded, with low coding level under EN ISO 14119. The STR1 series provides three coding options, and the difference is operational, not cosmetic.

Coding variant Actuator behaviour Coding level Response-time note
Universal (this model) Sensor accepts any actuator of the same type Low No added time
Unique Actuator must be taught in; sensor accepts only that actuator High +0.5 s per taught-in actuator
Permanent Actuator is permanently assigned; sensor accepts only that actuator High +0.5 s per taught-in actuator

latest company case about SICK STR1-SAFM0AC8: RFID Safety Switch — PFHD, Coding Level and Series Connection Guide  1

The practical boundary of universal coding is actuator substitutability. If a spare actuator is available on site, or if an actuator can be taken from another machine of the same model, the guard-monitoring function can be triggered without defeating the sensor itself. Unique and permanent coding remove that path: the sensor is bound to a specific actuator, and replacing it requires re-teaching (unique) or a replacement sensor-actuator pair (permanent).

EN ISO 14119 ties the coding level to the risk assessment’s evaluation of reasonably foreseeable defeat. If the guard is in a location where operators have both the incentive and the access to substitute an actuator — piece-rate work, frequent short-cycle access, a nearby machine with the same STR1 type — universal coding may not provide the required level of protection. The unique or permanent variant should be evaluated in that case, and the +0.5 s response-time penalty per taught-in actuator enters the stopping-distance calculation.

For applications where the risk assessment does not identify an actuator-substitution pathway, universal coding keeps spare-part management simple: one actuator type fits any sensor of this model, and no teaching step is required during replacement.

5. Installation: Alignment, Distances, and the Serial-Number Temperature Check

The Sao of 14 mm and Sar of 28 mm apply to frontal alignment at -10 to +70 °C. At -30 to -10 °C (serial numbers 1825+), Sao drops to 10 mm. The five actuation directions do not all provide the same switching distance; the response-range diagrams in the operating instructions are the reference for side and angled approaches.

Before mounting, check the serial number on the nameplate. A unit below serial 1825 in a -30 °C environment is outside its rated temperature range, regardless of what the catalog page says about the STR1 series.

The sensor and actuator should be mounted so that the actuator enters and leaves the response range without mechanical impact. The compact housing (40 × 18 × 26 mm) and three active surfaces give mounting flexibility, but the distance values are alignment-specific. A bracket designed around “14 mm” without confirming the approach direction may produce a switching point that differs from the frontal-alignment figure.

latest company case about SICK STR1-SAFM0AC8: RFID Safety Switch — PFHD, Coding Level and Series Connection Guide  2

6. Wiring: 8-Pin M12 and the Safety-Relevant Pins
Pin Function
1 AUX output (non-safety)