logo
products
CASES
Home >

Xiamen ZhiCheng Automation Technology Co., Ltd Cases

Events
Contact Us
Miss. Andy
86-0592-5636807
wechat +8618020763272
Contact Now
Latest company case about Siemens SCL Programming Upgraded Version: 12 Industrial Practical Cases

Siemens SCL Programming Upgraded Version: 12 Industrial Practical Cases

12 Industrial Practical Cases (1-6) Case 1: Motor Start-Stop Control scl FUNCTION_BLOCK FB_MotorControl VAR_INPUT StartButton: BOOL; StopButton: BOOL; OverloadSignal: BOOL; END_VAR VAR_OUTPUT RunningStatus: BOOL; FaultIndicator: BOOL; END_VAR BEGIN // Start-Stop Logic IF StartButton AND NOT StopButton AND NOT OverloadSignal THEN RunningStatus := TRUE; ELSIF StopButton OR OverloadSignal THEN RunningStatus := FALSE; END_IF; // Fault Indication FaultIndicator := OverloadSignal; END_FUNCTION_BLOCK   Case 2: Timer Application scl FUNCTION_BLOCK FB_DelayStart VAR_INPUT StartSignal: BOOL; DelayTime: TIME := T#5S; END_VAR VAR_OUTPUT OutputSignal: BOOL; END_VAR VAR DelayTimer: TON; END_VAR BEGIN DelayTimer(IN := StartSignal, PT := DelayTime); OutputSignal := DelayTimer.Q; END_FUNCTION_BLOCK   Case 3: PID Temperature Control scl FUNCTION_BLOCK FB_TempControl VAR_INPUT Setpoint: REAL; ProcessValue: REAL; END_VAR VAR_OUTPUT ControlOutput: REAL; END_VAR VAR Kp: REAL := 2.0; Ki: REAL := 0.05; Kd: REAL := 0.5; IntegralTerm: REAL := 0; LastError: REAL := 0; Timer: TON; END_VAR BEGIN // Execute periodically (100ms) Timer(IN := NOT Timer.Q, PT := T#100ms); IF Timer.Q THEN VAR Error := Setpoint - ProcessValue; IntegralTerm := IntegralTerm + Error; VAR DerivativeTerm := Error - LastError; LastError := Error; ControlOutput := Kp * Error + Ki * IntegralTerm + Kd * DerivativeTerm; ControlOutput := LIMIT(0.0, ControlOutput, 100.0); Timer(IN := FALSE); END_IF; END_FUNCTION_BLOCK Case 4: Production Line Queue Management scl FUNCTION_BLOCK FB_ProductionQueue VAR_INPUT NewOrder: BOOL; OrderID: INT; CompleteSignal: BOOL; END_VAR VAR_OUTPUT CurrentOrder: INT; QueueLength: INT; END_VAR VAR OrderQueue: ARRAY[1..50] OF INT; QueueHead: INT := 1; QueueTail: INT := 1; END_VAR BEGIN // New order enqueue IF NewOrder AND QueueLength < 50 THEN OrderQueue[QueueTail] := OrderID; QueueTail := QueueTail MOD 50 + 1; QueueLength := QueueLength + 1; END_IF; // Completed order dequeue IF CompleteSignal AND QueueLength > 0 THEN QueueHead := QueueHead MOD 50 + 1; QueueLength := QueueLength - 1; END_IF; // Current order IF QueueLength > 0 THEN CurrentOrder := OrderQueue[QueueHead]; ELSE CurrentOrder := 0; END_IF; END_FUNCTION_BLOCK   Case 5: Safety Gate Interlock Control scl FUNCTION_BLOCK FB_SafetyGate VAR_INPUT Gate1Closed, Gate2Closed: BOOL; EStopButton: BOOL; ResetButton: BOOL; END_VAR VAR_OUTPUT SafetyStatus: BOOL; END_VAR VAR LockoutStatus: BOOL := FALSE; LockoutTimer: TON; END_VAR BEGIN // Safety condition VAR AllGatesClosed := Gate1Closed AND Gate2Closed; // Emergency stop highest priority IF EStopButton THEN SafetyStatus := FALSE; LockoutStatus := TRUE; LockoutTimer(IN := TRUE, PT := T#10S); RETURN; END_IF; // Unlock logic IF ResetButton AND LockoutStatus AND LockoutTimer.Q THEN LockoutStatus := FALSE; END_IF; // Normal operation IF NOT LockoutStatus THEN SafetyStatus := AllGatesClosed; END_IF;
2025-07-03
Read more
1
Sitemap |  Privacy Policy | China Good Quality SICK Laser Sensor Supplier. Copyright © 2025 Xiamen ZhiCheng Automation Technology Co., Ltd . All Rights Reserved.