The Honeywell STD725 is a differential pressure transmitter within the SmartLine ST700 platform. It measures the pressure difference between two process taps and converts that difference into a two-wire 4–20 mA analog signal with HART digital communication. The published STD725 range is -400 to 400 inH₂O (-1000 to 1000 mbar), with a minimum span of 4 inH₂O (10 mbar) and a maximum turndown of 100:1.
The ST700 sensor architecture combines piezoresistive differential pressure sensing with on-chip temperature compensation and, on differential pressure models, static pressure compensation. This matters in applications where line pressure and ambient temperature move during normal operation, because those variables can otherwise shift the differential pressure reading.
![]()
The complete ordering code STD725-E1HS4AS-1-C-EHS-13S-A-31 carries configuration information beyond the base model. Two transmitters both labeled STD725 can differ in wetted materials, process connections, fill fluid, housing, approvals and calibration options. The base series specifications below describe what the STD725 platform can do; they do not by themselves confirm every material or approval encoded in a particular suffix string. That distinction is the central selection issue for this instrument.
The following table summarizes published STD725 series specifications. It is a platform-level reference, not a decode of every character in STD725-E1HS4AS-1-C-EHS-13S-A-31.
| Parameter | Published specification |
|---|---|
| Manufacturer | Honeywell |
| Product family | SmartLine ST700 |
| Model | STD725 |
| Product type | Differential pressure transmitter |
| Measurement technology | Piezoresistive sensor with on-chip temperature and static pressure compensation |
| Upper Range Limit (URL) | 400 inH₂O (1000 mbar) |
| Lower Range Limit (LRL) | -400 inH₂O (-1000 mbar) |
| Minimum span | 4 inH₂O (10 mbar) |
| Maximum turndown | 100:1 |
| Standard reference accuracy | ±0.05% of span; optional ±0.04% of span |
| Long-term stability | 0.020% of URL per year, over 10 years |
| Analog output | Two-wire, 4–20 mA |
| Digital communication | HART 7 |
| Response time | As fast as 100 ms |
| Adjustable damping | 0–32 seconds |
| Ambient operating temperature | -40°C to +85°C |
| Meter body temperature | -40°C to +125°C |
| Supply voltage | 10.8–42.4 VDC at terminals; intrinsically safe versions limited to 30 VDC |
| Enclosure protection | Type 4X / IP66 / IP67, depending on configuration |
| Process connections | Series options include 1/4-inch NPT female and 1/2-inch NPT |
| Wetted materials | 316L stainless steel standard; other materials subject to configuration |
| Hazardous-area approvals | Must be verified against the exact ordering code and nameplate |
Series specifications are drawn from Honeywell's published STD700 differential pressure technical documentation and product catalog data. The 0.05% figure is a reference accuracy under defined reference conditions; it is not a total installed error. Static pressure effect, temperature effect, turndown and analog output contribution should be evaluated separately for the actual configured span. The 0.020% URL/year stability figure is a published series value over 10 years and is not a substitute for site calibration planning.
Ambient temperature and meter body temperature are different limits. Process temperature must be checked against the meter body limit and the fill fluid, not against the ambient rating.
A differential pressure transmitter has two pressure ports. The high-pressure side (H) connects to the higher-pressure tap; the low-pressure side (L) connects to the lower-pressure tap. The instrument responds to the difference:
ΔP = P_H − P_L
![]()
On the ST700 platform, the piezoresistive sensor produces an electrical signal proportional to that difference. Honeywell's design adds on-chip temperature measurement and, for differential pressure models, static pressure measurement, so the transmitter can compensate the differential pressure reading for changes in line pressure and temperature. The compensated signal is then converted to the 4–20 mA loop output and made available digitally over HART 7.
For flow applications, the transmitter measures ΔP across a primary element; the flow rate is calculated separately by the control system using the primary element coefficients, fluid properties and operating conditions. The transmitter does not output flow directly unless the host system performs that calculation.
The STD725 covers -400 to 400 inH₂O with a 4 inH₂O minimum span. The 100:1 turndown figure describes the ratio between the upper range limit and the minimum span; it does not mean reference accuracy remains ±0.05% at every turndown. At high turndown, the absolute error in pressure terms is smaller, but the percentage-of-span error can increase depending on the accuracy statement being applied. Configure the span around the expected operating differential pressure rather than around the full URL.
ST700 differential pressure models measure static pressure on the sensor chip and use it, together with temperature, to compensate the differential pressure output. This is relevant in flow loops and filter monitoring where line pressure may vary independently of the differential pressure being measured. It does not eliminate static pressure effects entirely; the published static pressure effect should still be considered for the configured range.
The STD725 uses a two-wire 4–20 mA loop with HART 7 digital communication. The analog current can go to a PLC or DCS analog input, while HART provides a digital channel for configuration, range adjustment, diagnostics and device status. The host system, loop resistance and wiring arrangement must support HART communication; the presence of a 4–20 mA signal alone does not guarantee HART access.
The ST700 platform provides device diagnostics for conditions such as electronics faults, meter body configuration or memory errors, sensor communication issues and process variable range alerts. The platform also uses a modular meter body, display and electronics arrangement. Honeywell documents field-replaceable meter bodies, displays and electronics modules; replacement should follow the published service procedure so that calibration and configuration are preserved.
Across an orifice plate, venturi or other primary element, the transmitter measures the differential pressure that the element generates. The flow computer or DCS converts that ΔP to flow using the element bore, discharge coefficient, fluid density and expansion factor. The STD725 is a candidate when the expected ΔP falls within its 4–400 inH₂O span and the static line pressure is within the meter body rating.
![]()
A transmitter installed across a filter records the pressure drop between inlet and outlet. As the filter loads, ΔP tends to rise at comparable flow. The signal can be trended in a PLC or DCS and used with flow data to decide when inspection or replacement is due. Typical services include air filtration, water treatment, process liquid filtration and utility service filters.
![]()
In a hydrostatic level arrangement, the high side connects to the lower tap and the low side to the vessel vapor space or a reference leg. The measured ΔP is related to the liquid column height and density. Closed vessels require the low-side reference to account for vessel pressure. The transmitter's wetted materials and static pressure rating must match the process, and remote seals may be needed when the process is corrosive, viscous or at temperature extremes.
Differential pressure across strainers, piping sections, heat exchangers or pump suction and discharge can indicate changes in resistance. A ΔP reading on its own does not prove pump efficiency or equipment condition; it must be evaluated with flow, absolute pressure and temperature data. The STD725 is suitable when the expected loss is within its differential range and the line pressure is compatible with the selected meter body.
In chemical and petrochemical plants, material compatibility and hazardous-area certification usually drive the configuration more than the base accuracy figure. In water and wastewater service, wetted-material corrosion, suspended solids and impulse-line fouling are the practical concerns. The STD725 can serve these applications, but the suffix configuration must be matched to the actual fluid, pressure, temperature and area classification.
Connect the higher-pressure tap to the H port and the lower-pressure tap to the L port. Check port markings and the installation drawing before applying pressure. Reversed connections produce an inverted reading that can be difficult to diagnose later if the loop is ranged in the wrong direction.
For liquid service, arrange impulse lines so that gas pockets cannot accumulate on the measurement side. For gas service, arrange them so that condensate drains away from the transmitter. Slope, vent and drain valves, and isolation arrangements should follow the manufacturer's installation instructions and the site's process engineering standards. Impulse-line errors are a more common source of field error than transmitter electronics faults.
![]()
The differential range and the static pressure rating are separate limits. The STD725 series is rated for 400 inH₂O differential, but the meter body and process connection have their own maximum working pressure. Confirm both: the expected differential pressure must fall within the configured span, and the maximum line pressure must be within the meter body and connection rating.
![]()
Confirm supply voltage, loop resistance, polarity, grounding and cable requirements before wiring. For hazardous areas, use only the approval and electrical parameters shown on the nameplate and the applicable control drawing for the exact configuration. Do not assume that a generic ST700 manual applies to a specific approval suffix.
![]()
Honeywell's ST700 documentation recommends calibration verification at defined intervals. That interval is a reference recommendation, not a universal plant standard. The actual interval should reflect process criticality, operating conditions, historical drift and site procedures. During maintenance, inspect impulse lines, fittings, vent/drain valves and device diagnostics in addition to the transmitter calibration.
STD725-E1HS4AS-1-C-EHS-13S-A-31 is a configured instrument, not a generic catalog number. Publicly available ST700 ordering examples show that suffixes in the STD725 code position encode materials, fill fluid, process connection, housing, output, approval and calibration options. The table below gives the configuration questions that the code should answer; it is not a substitute for Honeywell's official model selection guide.
| Configuration item | What to confirm for this code |
|---|---|
| Wetted diaphragm and process head material | 316L stainless steel is common in STD725 examples; confirm for the E1 and subsequent characters |
| Fill fluid | Silicone oil is a common default in ST700 codes; confirm against process temperature and compatibility |
| Process connection | 1/4-inch NPT female is indicated by H in several ST700 examples; verify whether adapters or 1/2-inch NPT are involved |
| Housing and enclosure | Polyester powder coated aluminum is common; confirm the approval and ingress protection associated with the selected housing code |
| Output and communication | 4–20 mA with HART is the standard ST700 output; confirm whether the selected code includes HART 7 and any optional digital protocol |
| Hazardous-area approval | The approval code must match the installation area classification and the nameplate marking |
| Calibration and options | Calibration range, diagnostics level, tag and conduit options are encoded in later suffix groups |
Public ST700 ordering examples associate E1 with 316L stainless steel and silicone fill, H with 1/4-inch NPT, and H in the output position with 4–20 mA HART. Similar STD725 and STD720 codes use 13S and A-31 suffixes, but the exact meaning of those groups should be confirmed against Honeywell's current ST700 model selection guide before they are treated as fixed facts for this specific code. The practical point is not to guess the full decode; it is to require the supplier or Honeywell configuration record to confirm each item in the table above.
For a replacement or new purchase, the complete ordering code, the calibrated range and the nameplate approval string are the three documents that matter more than the STD725 family name.
Q1: What is the Honeywell STD725 used for?
The STD725 measures differential pressure in flow loops with primary elements, filter and strainer pressure-drop monitoring, hydrostatic level measurement and equipment pressure-loss monitoring. It outputs a 4–20 mA signal with HART 7 digital communication.
Q2: What is the STD725 measurement range?
The published STD725 range is -400 to 400 inH₂O (-1000 to 1000 mbar), with a 4 inH₂O minimum span and 100:1 maximum turndown. The configured range must be set within those limits and around the expected operating differential pressure.
Q3: What accuracy does the STD725 offer?
Published standard reference accuracy is ±0.05% of span, with an optional ±0.04% of span version. Reference accuracy is not total installed performance; static pressure effect, temperature effect and turndown should be included in the error budget for the configured span.
Q4: Can the STD725 measure flow?
Yes, when used with a primary element such as an orifice plate or venturi. The transmitter measures differential pressure; the flow rate is calculated by the control system or flow computer using the primary element and fluid data.
Q5: What must be checked before replacing an STD725?
Check the complete ordering code character by character, the calibrated range, process connection, wetted materials, fill fluid, static pressure rating, output/communication configuration, housing entry and hazardous-area approval. A matching STD725 model designation alone is not enough.
The STD725 is a differential pressure transmitter in Honeywell's SmartLine ST700 family, published with a -400 to 400 inH₂O range, a 4 inH₂O minimum span, 100:1 turndown, 0.05% reference accuracy and HART 7 communication. Its practical value depends less on the base model number than on whether the suffix configuration matches the process: wetted materials, fill fluid, process connection, static pressure rating and area approval.
For a new installation or a replacement, use the published series specifications to screen the platform, then verify STD725-E1HS4AS-1-C-EHS-13S-A-31 against Honeywell's current ST700 model selection guide or the original configuration record. The series data tells you what the STD725 can do; the ordering code tells you what this particular transmitter is.
Need a Honeywell STD725-E1HS4AS-1-C-EHS-13S-A-31 Differential Pressure Transmitter?
Send the complete model number, the process medium, the expected differential pressure range, the maximum line pressure, the process temperature and the area classification. We can check the configuration against the ordering code and confirm availability and quotation.
Placement: After the Product Overview’s second paragraph.
Filename: honeywell-std725-differential-pressure-transmitter.jpg
ALT: Honeywell STD725 SmartLine differential pressure transmitter.
Caption: Honeywell STD725 differential pressure transmitter for industrial process measurement.
Requirement: Use an actual photograph of the STD725 or a clearly identified STD725/STD735/STD775 family unit. Do not present a different model as the exact ordering configuration.
Placement: Under “How the STD725 Measures Differential Pressure."
Filename: differential-pressure-transmitter-measurement-principle.jpg
ALT: Differential pressure transmitter diagram showing high-pressure and low-pressure process connections.
Caption: The transmitter responds to the difference between the high-side and low-side pressures.
Placement: Under “Filter Differential Pressure Monitoring."
Filename: industrial-filter-differential-pressure-monitoring.jpg
ALT: Differential pressure measurement across an industrial process filter.
Caption: Filter loading appears as an increasing pressure drop at comparable flow.
Placement: Under “Flow Measurement with Primary Elements."
Filename: orifice-plate-differential-pressure-flow-measurement.jpg
ALT: Differential pressure transmitter connected to an orifice plate flow measurement system.
Caption: An orifice plate generates a differential pressure that the transmitter measures; flow is calculated separately.
Placement: Under “Installation and Commissioning Considerations."
Filename: industrial-differential-pressure-transmitter-installation.jpg
ALT: Industrial differential pressure transmitter installed with process impulse lines.
Caption: Impulse-line routing and high/low-side connection discipline determine field reliability.
Use descriptive anchors rather than repeating the primary keyword:
| Anchor text | Destination |
|---|---|
| Honeywell pressure transmitters | Honeywell product category |
| Differential pressure transmitters | Differential pressure transmitter category |
| Industrial pressure measurement | Pressure measurement category |
| Flow measurement instruments | Flow measurement category |
| Industrial process instrumentation | Process instrumentation category |
Honeywell, STD700 SmartLine Differential Pressure Technical Specification, 34-ST-03-121; Honeywell product catalog page lists the current revision dated 12/19/2025.
Honeywell, STD700 SmartLine Differential Pressure Technical Specification, 34-ST-03-101.
Honeywell, SmartLine ST700 Differential Pressure Transmitter product overview, process.honeywell.com.
Honeywell, ST700 model selection guide — required for authoritative decode of STD725-E1HS4AS-1-C-EHS-13S-A-31.
Publication note: The series specifications in this article describe the STD725 platform. The suffix configuration of STD725-E1HS4AS-1-C-EHS-13S-A-31 — including diaphragm material, fill fluid, process connection, housing, approval and calibration options — must be confirmed against Honeywell's current ST700 model selection guide or the original configuration record before publication of claims about those specific attributes.